{"product_id":"intrerupator-motor-cu-contactor-lc1-d3210-releu-de-protectie-32a","title":"Motor Starter with Contactor, LC1\/D3210, Overload Relay, 32A","description":"\u003cdiv class=\"cl-desc\"\u003e\n\n\u003csection class=\"cl-intro\"\u003e\u003ch2\u003eIndustrial motor starter with 32A contactor for motor protection\u003c\/h2\u003e\n\n\u003cp\u003eThe complete solution for starting and protecting electric motors up to 10 kW. Equipped with an LC1\/D3210 contactor and a thermal overload relay, this motor starter offers safe control and automatic protection against overloads. Ideal for industrial applications, workshops, and installations with electric machines.\u003c\/p\u003e\n\n\u003c\/section\u003e\u003csection class=\"cl-benefits\"\u003e\u003ch2\u003eWhat you get with this product\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAutomatic motor protection against overloads and short circuits, without equipment damage\u003c\/li\u003e\n\n\u003cli\u003eIntuitive control via clear Start\/Stop buttons, eliminating risk of operating error\u003c\/li\u003e\n\n\u003cli\u003eRobust ABS enclosure with cable compartments and quick mounting on rail or wall\u003c\/li\u003e\n\n\u003cli\u003eCertified compatibility with LE1D contactors, direct integration into existing installations\u003c\/li\u003e\n\n\u003cli\u003e32A switching capacity for motors up to 10 kW at 500-690V, wide application coverage\u003c\/li\u003e\n\n\u003cli\u003eComplete pre-wired kit, reducing installation time by over 50% compared to separate components\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003c\/section\u003e\u003csection class=\"cl-how\"\u003e\u003ch2\u003eHow it works and how to install it\u003c\/h2\u003e\n\n\u003cp\u003eThe starter operates by pressing the green button to start, which activates the contactor and powers the motor. The thermal relay constantly monitors the consumed current and automatically cuts off power if an overload is detected. The red stop button instantly disconnects the motor.\u003c\/p\u003e\n\n\u003cp\u003eInstallation is done by securing the enclosure on a DIN rail or with screws on the wall, connecting the power cables through the 4 ISO20 entries, then connecting the 230V AC control circuit and the motor. The terminals are clearly labeled, and the wiring diagram is printed on the inside of the cover.\u003c\/p\u003e\n\n\u003c\/section\u003e\u003csection class=\"cl-faq\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdiv class=\"cl-faq-item\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum motor power I can connect to this starter?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIt supports motors up to 10 kW at voltages between 500-690V AC, with a rated operational current of 32A in AC-3 mode.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"cl-faq-item\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs it difficult to connect if I'm not a licensed electrician?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eInstallation requires knowledge of industrial electricity and ANRE authorization. For safety, installation by qualified personnel is recommended.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"cl-faq-item\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I know if the thermal relay has tripped?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe relay has a visual trip indicator and requires manual resetting after the motor cools down and the cause of the overload is eliminated.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\u003csection class=\"cl-specs\"\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eContactor model\u003c\/td\u003e\n\n\u003ctd\u003eLC1\/D3210\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eRated operational current\u003c\/td\u003e\n\n\u003ctd\u003e32A AC-3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eConventional thermal current\u003c\/td\u003e\n\n\u003ctd\u003e32A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum motor power\u003c\/td\u003e\n\n\u003ctd\u003e10 kW at 500V AC \/ 10 kW at 660-690V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eControl circuit voltage\u003c\/td\u003e\n\n\u003ctd\u003e230V AC 50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eEnclosure material\u003c\/td\u003e\n\n\u003ctd\u003eDurable ABS, metal components\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMounting type\u003c\/td\u003e\n\n\u003ctd\u003eScrews or DIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCable entries\u003c\/td\u003e\n\n\u003ctd\u003e4x ISO20 (2 upper, 2 lower)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\n\u003ctd\u003eLE1D code\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003ePackage contents\u003c\/td\u003e\n\n\u003ctd\u003e1x Fully pre-wired motor starter\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/section\u003e\u003csection class=\"cl-warranty\"\u003e\u003ch2\u003eWarranty and support\u003c\/h2\u003e\n\n\u003cp\u003eThe product comes with a 24-month warranty according to Romanian legislation for manufacturing defects. 30-day return policy from delivery. Fast national courier delivery with SMS confirmation.\u003c\/p\u003e\n\n\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":56801604436299,"sku":"Q-5A006","price":31.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1032\/2067\/4891\/files\/Intrerupator-Motor-cu-Contactor_e2371076-bec5-46ea-aa5c-4c27fb8bcf54.png?v=1773834767","url":"https:\/\/classlights.eu\/en-eu\/products\/intrerupator-motor-cu-contactor-lc1-d3210-releu-de-protectie-32a","provider":"ClassLights","version":"1.0","type":"link"}